Relations sémantiques
Broader
Narrower
Exact match
Related
Particle density 110 experimental
-
Core metadata
Core metadata
is a Process | normalised method | laboratory test | geotechnical test | Concept | laboratory ground test category geotechnics version info 2 submitted by h.bressan@brgm.fr
Hélène Bressansubmitted on 5 Aug 2021 08:56:58.431 accepted on 5 Aug 2021 09:27:25.830 status status experimental is a register item
URI: https://data.geoscience.fr/ncl/Proc/110
showing version latest ⏷
Pane is loading...
The particle density can be determined by two methods, a pycnometer method by fluid displacement and a pycnometer method by gas displacement. The fluid pycnometer method applies to soil types with particle sizes under about 4 mm, or soils crushed to meet this requirement. Larger pycnometers are used for coarser materials. The particle size of soils suitable for testing in the gas pycnometer is limited by the dimensions of the specimen container of the particular gas pycnometer being used.
Download
Suggest feedback
Download formats available
RDF ttl | plain | with metadata |
RDF/XML | plain | with metadata |
JSON-LD | plain | with metadata |
CSV | plain | with metadata |
Export all | export |
-
geotechnics
- category
-
Process
- in scheme
-
55245.html
- isReferencedBy
-
Particle density
-
Détermination de la masse volumique de particules solides
- label
-
110
- notation
-
ISO 17892-3:2015
-
NF EN ISO 17892-3 Décembre 2015 (P94-512-3)
- source
-
Valid
- status
-
Process
- top concept of
All metadata properties
date accepted |
5 Aug 2021 09:27:25.830
|
||||
date submitted |
5 Aug 2021 08:56:58.431
|
||||
definition |
|
||||
description |
|
||||
item class |
normalised method
| laboratory ground test
| laboratory test
| Concept
| geotechnical test
| Process
|
||||
label |
|
||||
notation |
110
|
||||
register |
Process
|
||||
status |
status experimental
|
||||
submitter |
|
||||
type |
register item
|
||||
version info |
2
|